Past Corrective Actions

NumberNameTypeCommentStatusComplete
192Hunter TransformersManagement Review September 2025Certifications to be updated as part of recertification.Open
191Weekly Toolbox TalkImprovementWeekly WHS Inspectio & Toolbox to be implemented.Open
190Incident Investigation 14-07-2025WHSIncident Report, Evaluation, Design of doors updated to include locating lugs to support the weight of the door.,  Closed21-Aug-25
189Pallet Racking - Star DeltaAuditThe pallet racking does not meet the requirements of AS4084:2023., Identified Requirements, Signage, Signs must be permanently attached to the racking in a conspicuous location (typically at the end of each aisle or on the racking itself)., , Inspection, ,  , Competent Person, , Records, Records must be maintained, including:, , Date of inspection, Inspector’s name and qualifications, Observations and identified risks, Actions taken or required, , Keep records for a minimum of 5 years., Evaluation, , Racking inspected by competent person. - Inspection Certificate, Signage installed.Closed22-Jul-25
188Incident Investigation 15-10-2024WHSActions, , Hand Safety discussed at Toolbox Meeting 01-11-2024Closed19-Feb-25
187Incident Investigation 11-10-2024WHSActions, , Housekeeping discussed at Toolbox Meeting of 01-11-2024, Forklift SWMS reviewed and updated., Operators to resign SWMS, ,  Closed19-Feb-25
186Finding #20 - Spill KitsAuditNoted that both spill kits in WA are together and not located near either Chem storage. Not easily accessible (obstructed)., Evaluation, Spill kits now located throughout the plant.Closed17-Feb-25
185Finding #19 - Forklift InspectionsAuditAt the time of audit, there was no evidence that the forklift daily pre-starts were being documented in WA., Evaluation, , SWMS updated., Inspection frquency daily recorded using the QR Code Inspection Form., , Forklift Inspections now conducted daily.Closed2-Aug-25
184Finding #18 - Risk MatricesAuditDuring the audit, it was a number of risk matrices were sighted with sometime conflicting risk ratings and categories., Evaluation, Matrix in the procedure Risk Management updated to reflect the matrix used in the Aspects RegisterClosed27-Sep-24
183Finding #17 - Roles & Responsibilities MatrixAuditRoles and Responsibilities Matrix reviewed in WA did not have a corresponding key / legend., Evaluation, Roles & Responsibilities Matrix updated to include legend.Closed27-Sep-24
182Finding #16 - PoliciesAuditHard copy policies sighted on the walls in the WA main lunchroom were dated 2019 (and not the current version.), Evaluation, Hard copy policies to be removed from notice boards and replaced with QR Codes to allow access to current policies.Closed17-Feb-25
181Evacuation Plan BlockedAuditItems in front of Notice Board blocking Evacuation Plan, Evaluation, Obstructions moved.Closed13-Sep-24
180Incident Investigation 12-09-2024WHSEvaluation, Fragments entered under eye protection (glasses). Goggles to be used when grinding., To be discussed at the next Toolbox MeetingClosed13-Sep-24
179Fire ExtinguisherAuditExtinguisher access blocked., Evaluation, Obstacles removed.Closed13-Sep-24
178Compliance Review 2025Legislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, No Actions Required,  Closed18-Feb-25
177Toolbox TalksAuditIt was noted that Toolbox Talks are not being conducted at the agreed frequency., Evaluation, Toolbox talks taking place - records not correctly generated., Reviewed function of Google Forms to correct operational issues.Closed15-May-24
176Tag & Test 2024AuditTag & Test is due on 01-03-2024, Noted Tag & Test completed on 20-03-2024Closed16-Apr-24
175SD - Racking Safe Working Load IdentificationAuditSome of the SWL stickers have come off from the storgae racks., , Evaluation, Racking to be reorganised to create more space.,  Closed11-Sep-24
174Incident Investigation 01-02-2024WHSEvaluation, Discussed at Toolbox Meeting 15-02-2024Closed11-Sep-24
173Finding #14 Lifting SlingsExternal AuditAll new lifting equipment was purchased on in June 2022 and was inspected and in good condition. The inspection regsiter was not updated, and the lifting equipment did not have tags indicating this had been inspected periodically. RF#14 remains open and has not been upgraded to a MNCR as it is administrative only., but will require review next audit., Evaluation, , New lifting equipment currently re-purchased annually., Slings registers in place.Closed11-Sep-24
172Incident 12-12-2023WHSEvaluation, , Manual handling discussed at Toolbox Talks, All employees to re-do WHSQE Induction - ongoing.Closed15-Mar-24
171SWMS Sign Off - Electrical TestingTestingEvaluation, SWMS Signed OffClosed9-Sep-24
170Compliance Review 2024Legislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, No Actions Required,  Closed2-Sep-24
169GT - 2.5 MVA Transformer FaultFaultClient: Nuigini Electrical, Job Reference No: 36882, Serial No: 26663-02, Evaluation, Some of the copper conductors and copper straps weresalvaged and successfully reused on the new windings.However, there was still roughly 50kg of copper wasted, yet withsome value still to be recovered through scrapping., Additionally, a total of 20h of labour were spent in winding the 3unused coils and reworking the written off coils to recovermaterials., A meeting was called with the winders regarding the importanceof checking the build up of a winding job as it progresses andstopping it before starting another coil if an issue is noticed, andalso how to double check the estimated build up noted on thedesign sheet and how much space you have available/left atany point during the winding., Actions taken:, , Design review and update, Team meeting on practices, , No further actions needed.Closed31-Aug-23
168Incident Investigation - 31-07-2023WHSActions, , Review of circumstances of the incident with the test engineer., Review test bay setup to reduce the risk of man made short circuitsClosed1-Aug-23
167Inclusion of DesignSales - Grant TransformersProcedure to be updated to include Design as per Scope Expansion - Management Review 15-08-2022, Evaluation, Procedure updated to include in house design.Closed18-Apr-23
166Manual Handling TrainingManagement Review September 2022Manual Handling to be presented on factory employees., Evaluation, Manual handling training presented to selected factory staff.Closed19-Dec-22
165Scope StatementsManagement Review September 2022The Scope Statements for Grant Transformers and Star Delta are to be consolidated into one statement., Evaluation, Scope statements consolidated in Management System Manual Closed18-Apr-23
164Incident Investigation 08-07-2022WHSActions, , SWMS for Forklift Operations developed and implemented., SWMS includes use of jibClosed12-Aug-22
163GT - Small Transformer FaultFaultActions, Discussions with Production Staff  - More attention during winding and care with steel lamination during stacking for the future. Closed12-Aug-22
162SD - 90kVA Txf coil wrong windingFaultOne coil of 90kVA wound in the opposite direction., Actions:, , Winder to wind all 3 coils in a batch so that he can wind them all in the same direction., Supervisor instructed not to stop winders when winding large coils to do urgent jobs.,  Closed12-Aug-22
161Incident Investigation 13-06-2022WHSProperty Damage., For imformation only., No further actions required.Closed15-Jul-22
160GT - Lifting SlingsAuditLifting Slings - Require inspection & Tagging, Actions, , Old lifting slings replaced with new slings., Slings Register established.Closed9-Jul-22
159Incident Investigation 10-06-2022WHSTransformer Oil leaking from the rear of the small oven., , Actions, , Oven to be replaced. New oven on order., , Oven replaced August 2022Closed10-Aug-22
158Incident Investigation - 14-04-2022Incident Reporting & InvestigationOil Spill by csutomer personnel while filling transformer with oil., Actions, , Minor oil spill - cleaned up with no risk of further contamination., Incident used as a drill for Spill Response:, , Spill Kit deployed, Oil spill effectively contained through use of spill kit, Previously delivered training on spill response deemed effective.Closed1-Jun-22
157Compliance Review 2023Legislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, No Actions Required,  Closed7-Nov-23
156GT - HousekeepingAuditGeneral housekeeping in the factory area requires attention., Actions, , New cabinets installed, Spill kit updated, New workbench, Two new storage cabinets, one for the epoxy mix chemicals and another one outside of the factory for gas cylinders, Empty oil drums removedClosed11-Aug-22
155GT - Used ExtinguishersAuditUsed extinguishers to be removed from the factory area., Actions, , Used extinguishers removed., One missing extinguisher replaced., ,  Closed15-Jul-22
154Induction TrainingAuditThree new employees are yet to complete the Induction training., Actions, The three employees in question did not remain with the company.Closed30-May-22
153SD - Lifting GearAuditLifting gear requires inspection., Actions, Old lifting gear replaced.Closed15-Jun-22
152SD - Updated Evacuation PlanAuditThe updated Evacuation Plan is not displayed in the factory., Actions, Evacuation Plan UpdatedClosed8-Aug-22
151Eziweld 801SDS - Ezi Weld 801 , , Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
150Fire ExitsAuditNew exit added to rear of building., Evacuation Plan to be updated., Actions, Evacuation Plan updated 08-04-2022Closed11-Apr-22
149Update NamesImprovementAdd and remove names from forms., Actions, All forms updated.Closed31-Mar-22
148Wong Terminals on Exectronics JobFaultWas supplied with orange terminals, should be EDS or weidmuller terminals for Railway TransformersClosed22-Mar-22
147Inspection Issues - VarleenInspection Records 2022 VarleenOrder Number: 573671, Serial Number: 26775-01/02, Actions, , Identified issues corrected in house., Varleen supplied Transformer Inspection Report., Varleen invoiced for repairs.Closed12-Mar-22
146Incident Investigation - 02-03-2022WHSInvestigation, , Accidental contact while testing causing arc, , Actions, , High voltage gloves to be used to prevent arcing, Review of SWMS for Testing, Re-training of staff in testing.Closed10-Jun-22
145Reporting RequirementsIncident Reporting & InvestigationThe procedure does not clearly specify the type of injuries/incidents that must be reported., Actions, Procedure updated to include definitions of notifiable incidents along with the reporting methods by Juridistiction, Current Version 02-03-2022Closed2-Mar-22
144Finding #14 - Lifting Slings & Pallet RackingAuditAt the time of the audit, it was noted that some slings and pallet raking did not have an up-to-date SWL inspection / tag on them., Actions, , Regular Pallet Rack Inspection developed and Implemented, Annual Inspection included on the Audit Schedule:, , Grant Transformers, Star Delta, , , Lifting Slings included in Rack Inspections program and monthly Factory InspectionClosed10-Jun-22
143Finding #13 - Factory InspectionsAuditIt was noted during the audit that not all of the factory inspections had been completed as per Grant Transformer requirements., Actions, , Monthly Factory Inspections re-instated at both Grant Transformers & Star Delta, Factory Inspection Schedule established in the Audit Schedule:, , Grant Transformers, Star Delta, , , Identification of previous and next Factory Inspection now included in monthly Factory InspectionClosed10-Jun-22
142Finding #12 - Forklift Prestart ChecksAuditIt was noted during the audit that not all of the forklift prestart’s had been completed as per Grant Transformer requirements, Actions, , Weekly Forklift Pre-Start Inspections re-instated at both Grant Transformers & Star Delta, Identification of previous and next forklift inspection now included in monthly Factory InspectionClosed10-Jun-22
141Finding #11 - Environmental DrillsAuditDrills and other activities are held to test these procedures. Reviewed minutes for drill conducted 10/09/2021. At the time of the audit limited environmental drills have been conducted., Actions, A separate Environmental Drill has been added to the Audit ScheduleClosed15-Mar-22
140Finding #10 - Toolbox MeetingsAuditAt the time of the audit not all toolbox meetings had been held in WA as per the schedule., Actions, , Monthly Toolbox Talks re-instated at both Grant Transformers & Star Delta, Identification of previous and next Toolbox Talk now included in monthly Factory InspectionClosed10-Jun-22
139Finding #9 - LogosAuditIt was noted that the certificates accessed via the Grant Transformers website are from their previous provider Bureau Veritas and will need to be updated to the Global-Mark certificates.,  , The Global-Mark logo used on the Star Delta website is not the correct one and will need to be updated., Evaluation, , Grant Transformers Logo updated to G-M IMS Logo, Global-Mark logo on Star Delta website updated to the correct (IMS) logo.Closed2-Mar-22
138Spill Response RehearsalEvacuation Plan - 89 Beringarra Avenue, MalagaActions, , Oil spill incident on 14-04022 used as environmental incident rehearsal., Outcomes satisfactory.Closed14-Apr-22
137Finding #8 - WHS PolicyAuditWhilst it is implied, the WHS Policy does not include clear commitments to the elimination of hazards and reduction of risks, providing safe and healthy working conditions for the prevention of work related injury and ill health, and to the continual improvement of the WHS management system., Evaluation, Policies for Grant Transformers & Star Delta updated to include the statement - In particular we are committed to the elimination of hazards and reduction of risks, providing safe and healthy working conditions for the prevention of work-related injury and ill health, and to the continual improvement of the WHS management system.Closed16-Sep-21
136ElkimaAuditSupplier to be removed from Key Suppliers List, Evaluation, Elkima removed from Key Suppliers List, Records maintained for future reference.Closed14-Sep-21
135Add Suppliers to Key Suppliers ListAuditAdd new suppliers to Key Suppliers Lsit, Evaluation, Suppliers added:, , SWEM, Alce, HikarClosed14-Sep-21
134GT - Varelen 2000kVA 11kVVarelenClosed8-Sep-21
133SDS Paints Grant TransformersChemicals RegisterAdd new paint items at Grant Transformers, Evaluation, All SDS for Paint and associated substances have been added to the Chemicals RegisterClosed18-Sep-21
132Mineral TurpentineSDS - Mineral TurpentineActions, , Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed8-Aug-22
131Methylated SpiritsSDS - Methylated SpiritsActions, , Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed8-Aug-22
130Compliance ReviewLegislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, The Standards for the Use & Care of Synthetic Fibre Lifting Slings should be included in the Register,  Closed9-Jun-22
129Organisation Chart - Roles & ResponsibilitiesOrganisation Chart - Grant TransformersThe current organisation chart is out of date, Evaluation, Organisation Charts updated.Closed28-Aug-21
128Incorrect LinksAuditSome of the links in the Procedure 03.13 Legislation & Legal Compliance are incorrect., Evaluation, Links updated to reference current Legislation RegisterClosed17-Aug-21
127Ultimeg 2000/372SDS - Ultimeg 2000/372Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed14-Aug-22
126Test Equipment - Naval Group Audit Finding #10AuditIMTE which is found to be out-of-calibration shall be immediately taken out of service, returned to the appropriate certified organisation for re-calibration if repairable and product re-checked to ensure that the specified accuracy is achieved. However this process is not documented., Evaluation, Procedure 03.09 Operations updated to detail the actions in the event of test equipment out of calibratrion.Closed21-May-21
125Determination of Capability - Naval Group Audit Finding #8AuditFurther clarification note required for 'Determination of Capability', Evaluation, Procedure 03.03.01 Sales - Grant Transformers updated to include Determination of CapabilityClosed21-May-21
124Root Cause Analysis - Naval Group Audit Finding #13AuditRoot Cause Analysis Training plan is being roll-out. Need training completion and implementation., Evaluation, Root cause analysis training held as part of July Toolbox meeting.Closed21-Jul-21
123Material Usage Data - Naval Group Audit Finding #12AuditRaw material eg copper wire, steel plate, bobbin batch or datecode not recorded on Production Job sheet. , Evaluation, The fitter notes the bin or bobbin number on the process control sheets (production pack)Closed19-May-21
122Waste Material - Naval Group Audit Finding #11AuditWaste or scrap material eg copper wire and cable located on Production floor not clearly identified., Evaluation, Waste area identified by green lines.Closed19-May-21
121Calibration Provider - Naval Group Audit Finding #9AuditCalibration label has equipment #, calibration due date. However HK Calibration Technologies is not NATA or equivalent accredited facility. The test results are traceable via NATA endorsed Test Report., Evaluation, Test results are traceable., No further action required.Closed22-Sep-21
120Environmental Risks - Naval Group Audit Finding #7Audit1) The SDS hardcopy is not available @ varnish station during the audit., 2) 'Lunch Area' is obstructing the forklift path., Evaluation, , SDS available at varnish station, , .​, , Fitted yellow lines to lunch area., , ,  Closed17-May-21
119CDIC Website - Naval Audit Finding #3AuditAwareness of the Centre for Defence Industry Capability (CDIC) website., Evaluation, Reference to the CDIC Website included in the Legislation Register under Customer RequirementsClosed17-May-21
118Control of Non Conforming Product - Naval Group Audit Finding #2AuditReject/Hold tag or quarantine area not available during the audit. Not Compliant to ISO9001:2015 Clause 8.7.2, Evaluation, Designated Quarantine Areas implemented, identified by red lines on the floor.Closed17-May-21
117Non Conforming Outputs - Naval Group Audit Finding #1AuditNo documented evidence on the Control of nonconforming outputs. Not Compliant to ISO9001:2015 Clause 8.7.1, Evaluation, , Reject tags implemented to identify non conforming product., Operations procedure updated accordingly.Closed17-May-21
116Barriers to ParticipationAuditIt is not clear how the barriers to participation are minimised., Evaluation, , Arrangements to address the requirements of USI 45001 Clause 5.4 detailed in the Risk Assessment Employee Participation, Procedure Consultation & Communication updated accordingly.Closed11-Jul-21
115SD - Chemical StorageAuditChemical Storage is inadequate., Evaluation, Additional flammable storage cabinet added., Housekeeping satisfactory, No further actions required.Closed19-May-21
114SD - Tag & TestAuditTag & Test is not yet complete., Evaluation, Tag & Test completed.Closed14-Sep-21
113GT - Purchasing Approvals - OFI #1AuditThe purchase orders generated from the MYOB requires approval from the management (for correctness) prior to sending to suppliers. The approval sometimes verbally granted or sometimes by initialling the hardcopy of the purchase order. The approval of the purchase orders could be programmed in the MYOB., Evaluation, , Purchasing procedure reviewed and updated to include revised purchase approvals process., MYOB will not be updated.Closed12-Jul-21
112GT - Supplier Evaluation - OBS #5AuditAlthough supplier performance review is regularly conducted to medium and high risk suppliers, the evaluation could be extended to internal supplier (Delta Star) and powder coating provider (Camboon Powder Coaters Pty Ltd)., Evaluation, , Camboon Powder Coaters have been added to the Key Suppliers list., Grant Transformers continues to merge with Star Delta, therefore is not considered a supplier.Closed31-May-21
111GT - Soldering Wire - OBS #4AuditAlthough the MSDS file and register is maintained and kept at the manufacturing area, the SDS for the soldering wire was not available and cannot be verified at the time of the audit., Evaluation, , Soldering wire added to Chemicals Register, SDS available.Closed12-Jan-21
110GT - Compressor Certificate of Registration - OBS #3AuditThe certificate of registration of the compressor on site could be displayed on the plant/equipment shed., Evaluation, Certificate of Registration not available., Compressor removed from service.Closed22-Mar-21
109GT - Gantry Crane - OBS #2AuditAlthough the gantry crane was downgraded into a lower SWL and was isolated, the approved SWL of the crane could be clearly indicated., Evaluation, SWL downgraded to 1000 KGClosed31-May-21
108Soldering - OBS #1AuditThe risk register at the factory operations could be reviewed to determine the hazards and risks associated to soldering activity and the new location., Evaluation, Risk Assessment Soldering developed.Closed6-Jan-21
107Purchasing ProcedurePurchasing & Supplier ControlProcedure to be updated - see attached., Evaluation, Procedure updated in accordance with request.Closed30-Nov-20
106GT - Varelen 2500kVA 11kV/1000vVarelenEvaluation, Refer attached Corrective Action ReportClosed15-Jan-21
105GT - Varelen 5000kVA 11kV/11kVVarelenEvaluation, Corrective Actions detailed in supplier responses for:, , 2000 kVA Transformer, 2500 kVA TransformerClosed29-Jan-21
104GT - Varelen 2000kVA 11kV1050vVarelenEvaluation, Refer attached Corrective Action ReportClosed15-Jan-21
103SD - Evacuation DrillManagement Review August 2020Evacuation Drill - Star Delta., Evaluation, Evacuation Drill completed.Closed25-Aug-21
102SD - Fire Warden TrainingManagement Review August 2020Fire Warden Training - Star Delta., Evaluation, Fire Warden Training completed., , Jaideep Reedy, Steve Borrel, Refer Training RecordsClosed19-May-21
101SD - Environment Policy.Management Review August 2020Develop Star Delta Environment Policy., Evaluation, Environment Policy in place.Closed1-Mar-21
100CertificationManagement Review August 2020Consolidation of certifications to be examined., Evaluation, Proposal received., Decision to be made.Closed
99Sales & OperationsManagement Review August 2020The processes for Sales and Operations are to be examined and consolidated., Evaluation, , Sales procedures to remain seperated due to minor differences., Operations procedures consolodated.Closed21-May-21
98Organisation ChartsManagement Review August 2020Update Organisation Charts., Evalualuation, Organisation Charts updated for Group Business Plan 2020Closed20-Oct-20
97Jointing Compound CopperSDS - Jointing Compound CopperSDS UpdatedClosed9-Jun-22
96Customer Satisfaction MeasurementAuditThe Procedure 03.03.02 Sales - Star Delta could better reflect the current methods for managing customer satisfaction., Evaluation, Procedure updated to reflect current methods.Closed19-Oct-20
95Nickel Anti-SiezeSDS - Premium Nickel Anti-SiezeActions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed14-Aug-22
943 in 1 Multipurpose OilSDS - 3 in 1 OilActions, , Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed10-Aug-22
93White Lithium GreaseSDS - White Lithium Grease , , Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
92GT - Varelen 1000 kVA TransformerVarelenClosed1-May-20
91Eziweld 801SDS - Ezi Weld 801SDS UpdatedClosed11-Apr-22
90Megapoxy HSDS - Megapoxy HActions, , Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed10-Aug-22
89Contact OLSDS - Contact OLActions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
88Cutting & Drilling OilSDS - Cutting & Drilling Oil , , Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
87Brake CleanerBrake CleanerActions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed14-Aug-22
86Stainless Steel CleanerSDS - Stainless Steel CleanerActions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed14-Aug-22
85Envirotemp FR3SDS - Envirotemp FR3 , , Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
84Envirotemp FR3SDS - Envirotemp FR3Evaluation, SDS UpdatedClosed14-Sep-20
83SDS Transformer OilChemicals RegisterThe Chemicals Register does not contain an SDS for Transformer Oil., Evaluation, SDS for Envirotemp FR3 added to RegisterClosed14-Sep-20
82Site Transformer WorksOnsite Transformer WorksDocuments required for customer to change Oil Level Gauge replacement.Closed11-Sep-20
81SD - Fire Extinguishers Out of TestAuditEvaluation, Out of Date Fire Extinguishers removed.Closed7-Oct-20
80Evacuation Plan Rehearsal Grant TransformersAuditA rehearsal of the Evacuation Plan has not yet been conducted at the new premesis., Evaluation, Evacuation Drill Conducted 08/09/2020Closed8-Sep-20
79SD - Safety Data SheetsWorkplace Inspection Grant TransformersSDS Out of Date, Refer Factory Inspection 13/08/2020, Evaluation, Chemicals Register UpdatedClosed8-Sep-20
78SD - Chemical StorageWorkplace Inspection Grant TransformersChemical Storage requires attention., Refer Factory Inspection 13/08/2020, Evaluation, Chemical clean up undertaken., Further reviews to take place as part of regular inspections.Closed16-Oct-20
77SD - Trip HazardsWorkplace Inspection Grant TransformersSlip & Trip Hazards - Leads on floor., Refer Factory Inspection 13/08/2020, Evaluation, Trip Hazards Removed, Issues Raised at Toolbox Meeting 13/08/2020Closed19-Aug-20
76SD - Tag & TestWorkplace Inspection Grant TransformersNo all equipment is Tested & Tagged, Refer Factory Inspection 13/08/2020, Evaluation, Tag & Test to be conducted October 19Closed16-Oct-20
75SD - Tortech Enclosure without an Enclosure ScrewFaultDouble quality check on Tortech Jobs, Evaluation, Additional inspection protocol developed for strategic customers.Closed8-Sep-20
74GT - Paul LeeTrainingWHSQE Induction Not Yet Completed, Evaluation, Completed 13/08/2020Closed13-Aug-20
73Compliance ReviewLegislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, No Actions Required,  Closed28-Aug-21
72Evacuation Plan UpdateAuditEvacuation Plan to be developed for 89 Beringarra Ave, Malaga WA, Evaluation, Evacuation plan developed and updated for new premesis.Closed4-Sep-20
71GT - Customer Complaint - MagellanCustomer ComplaintItem Information, ,  Part No: GT-26533., J/N 25906, 65Amp 1.04mH Inductor Transformer, , Faults, , The Inductor cable lugs came out of lug., Transformer Cable too short and poor Lug quality., No contact.at the Earthing PointClosed19-Jun-20
70WD40SDS - WD40Actions, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed8-Aug-22
69SD - Reviews Transferred from Previous SystemImprovementClosed12-May-20
68GT - Google Drive Inspection RecordsInspection RecordsGoogle Drive records are no longer available., Evaluation, Records re-created, Issues resolved, Forms now working correctly.Closed5-May-20
67Covid 19 InfectionImprovementEffects of the Coronavirus on business activities., Evaluation, , Coronavirus Management Plan, Pandemic added to Risk Register, Pandemic added to Business Continuity Plan, Toolbox Meeting to implement Social Distancing - Minutes attached.Closed6-Apr-20
66GT - Factory HousekeepingPurchasing & Supplier ControlFactory Housekeeping requires attention., Evaluation, Clean up conducted. Housekeeping satisfactory., Refer Plant Inspection 06-05-2020Closed6-May-20
65Damage by transportCustomer Complaint2MVA 11/1kV Transformer H.V terminal was damage by transport when getting delivered to our premises, INV  33970Closed27-Apr-20
64TrefolexSDS - TrefolexActions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed14-Aug-22
63Warranty ClaimCustomer ComplaintTransformer has a phase to phase faultClosed2-Apr-20
62GT - Transformer - Incorrect SupplyCustomer ComplaintTransformer HV and LV Plates supplied as steel. Should be aluminium., Drawings & Correspondence attached.Closed
61Wartsila #04AuditA better description of the application of Root Cause Analysis for supplier faults is required., Evaluation, Description of the circumstances where Root Cause Analysis is used included in procedure.Closed23-Sep-19
60GT - OFI #2 - 2019 Process DocumentationAuditAlthough the manufacturing process is very well documented, it could be improved by marking relevant cells as ‘N/A’, ie: BoM cells which are not required during a transformer build., Evaluation, Production documentation updated. Star Delta format adopted.Closed14-Dec-20
59OFI #1 - 2019 Toolbox MeetingsAuditAlthough Toolbox Meetings provide a good forum for raising issues, it could be improved by arranging periodic Talk Topics, ie: Heat Stress, Electrical Safety, Trip Hazards, Hand Safety, etc., Evaluation, , Training materials developed for Manual Handling (attached) - presented October, Additional materials under development., ,  Closed2-Dec-19
58Observation #10 First Aid SuppliesAuditNot all 1st aid supplies are in-date, ie: Burnaid and Irrigation Solution, Evaluation, First Aid supplies updated., Invoice attached.Closed20-Jan-20
57Observation #9 Waste Management ProcedureAuditAlthough documented in Draft format, the Waste Management Procedure should be finalised., Evaluation, Draft process issued as WMS.012Closed2-Dec-19
56Observation #8 Operational HazardsAuditAlthough most operational hazards are identified, some plant is not identified, ie: Drill & Mill Machines, Bench Grinder, etc, Evaluation, Additional Risk Assessments developed:, , Bench Grinder, Drill Press, Milling MachineClosed2-Dec-19
55Observation #7 Incoming Transformer InspectionAuditTransformers manufactured in Turkey was evaluated and it was noted that checks are carried out, however the results are not recorded., Evaluation, , Incoming inspection formalised, Inspection Form createdClosed1-Nov-19
54GT - Observation #6 RecordsAuditNot all documents maintained as ‘Records’ are registered as documented information, ie: Machine Maintenance Check sheet, BoM – Activity Sheet., Evaluation, Records added to Records Register:, , BOM Activity Sheet, Machine Maintenance ChecklistClosed2-Dec-19
53Observation #5 Chain of ResponsibilityAuditAlthough the Legal Register is comprehensive, it doesn’t list the Chain of Responsibility requirements for Heavy Haulage., Evaluation, WA Department of Transport advises that the provisions of the National Heavy Vehicle Laws do not apply in Western Australia. Refer attached Fact Sheet., No Further Action Required,  Closed30-Aug-19
52Observation #4 Toolbox MeetingsAuditAlthough the implementation of internal communications has commenced via Toolbox Meetings, there have only been 2 meetings, as per the schedule., Evaluation, , Toolbox meetings held monthly., , Records available, , , Follow up Action scheduled for review after first quarter 2020.Closed7-Feb-20
51Observation #3 Job DescriptionsAuditAlthough most positions are defined in Job Descriptions, the role of the Management System Coordinator is not., Evaluation, , Roles and responsibilities withing the system have been summarised in the Roles & Responsibilities Matrix, Management System Coordinator included in MatrixClosed18-Dec-19
50Observation #2 Environmental Aspects RegisterAuditThe Environmental Aspects and Impacts Register identifies ‘Significant Aspects’ as any aspect resulting in SIGNIFICANT or HIGH assessment, but the procedure identifies criteria as MODERATE or HIGH., Evaluation, , Software updated to include new Environmental Aspects Register. Aspects Register has the following features:, , Items identified in Aspects Register contain Residual Risk after the application of control measures, Identifies significant aspects, Identifies Aspects by location and situation, , , Process Map maintained to:, , Identify Business Processes as an input to the Aspects Register, Identify Initial Risks, , , Procedure Risk Management updated.Closed18-Dec-19
49Observation #1 Risk Management ProcedureAuditThe Risk Management Procedure (03.02) references Work Health & Safety Regulation 2011, not the WA Legislation., Evaluation, , Legislation reference under Review of Control Measures updated to reference the WA Legislation, Procedure re-issued 06/08/2019Closed18-Aug-19
48Incorrect DeliveryCustomer ComplaintTransformer Incorrect delivery, Evaluation, , Deliveries from different purchase orders not to be consolidated.Closed2-Sep-19
47Wartsila #03 Suppliers Code of ConductAuditCompany complies with Wärtsilä's requirement for human rights, child and forced labour. Company do have its Code of Conduct and also could not be verified that company ensures that its suppliers complies with Wärtsilä's defined social requirements., Evaluation, Suppliers sent the attached notification.Closed9-Aug-19
46Wartsila #02 Business Continuity PlanAuditCompany has risk assessment performed and various business risks are identified however Business Continuity Plan do not exist., Evaluation, , Business Continuity Plan developed., Draft issued for review., Draft Approved - MDS, Document issued 09/08/2019Closed9-Aug-19
45Wartsila #01 Quality Control PlansAuditCompany has quality control plans for its own production however during the audit the sub supplier and sub contractors' product approval report could not be verified., Evaluation, Formal Transformer Inspection Plan createdClosed9-Aug-19
44GT - Chain of ResponsibilityLegislation SummaryThe Chain of Responsibility and the National Heavy Vehicle legislation should be reviewed in light of the importation and transport of large transformers., Evaluation, The National Heavy Vehicle Legislation as currently written does not apply in Western AustraliaClosed2-Dec-19
43Potential EmergenciesEmergency ResponseThere would be benefit in adding the following situations to the list of Potential Emergencies:, , Electrocution, Serious Injury, , Evaluation, Procedure Emergency Response updated.Closed2-Dec-19
42WHS TargetManagement Review August 2019An additional WHS Target is required., Evaluation, Toolbox Meetings and Factory Inspections added to WHS TargetsClosed2-Dec-19
41GT - Management System Coordinator ResponsibilitiesManagement System ManualThere would be benefit in detailing the responsibilities of the Management System Coordinator within the system., Evaluation, Management System Coordinator added to the Roles & Responsibilities MatrixClosed18-Dec-19
40Area of Concern #3 WMS ReferenceAuditThe risk register doesn’t references applicable WMS relevant to specific hazards, ie: Winding Operations and Competency Training, Evaluation, Documents updated to reference supporting Risk Assessmentsa and Work Method Statements:, , Risks Register, Risk Assessment Factory OperationsClosed3-Jul-19
39Area of Concern #2 Incorrect Legislation ReferenceAuditThe H&S Policy doesn’t refer to WA specific legislation., Evaluation, Managed under Review #1873Closed1-Jul-19
38Area of Concern #1 Job DescriptionsAuditAlthough PDs were readily available, there were some variations in format and content, ie: experience., Evaluation, Standardised format for Position Descriptions implemented., Position Descriptions included for:, , Factory Manager, Factory Staff, Technical Service & Accounts, , Experience requirements included as approproate.,  Closed1-Jul-19
37WD40SDS - WD40SDS UpdatedClosed12-Jun-20
36Incorrect SpecificationFaultTransformer made to incorrect specification., Evaluation, Emphasis on checks during production cycle., Review during next Internal Audit - June 2020Closed2-Sep-19
35Root Cause AnalysisCorrective Action & Continual ImprovementThere would be benefit in the inclusion of techniques for the determination of root casue., Evaluation, Work Method Statement Root Cause Analysis introduced to detail RCA techniques.Closed2-Jul-19
34Legislation ReferenceWork Health & Safety Policy - Grant TransformersThe policy does not reference the WA OHS Act., Evaluation, Policy updated to reference the Occupational Safety & Health Act 1894, Current Version 29/06/2019Closed29-Jun-19
33GT - ForkliftAuditThere are operational/safety issues related to the forklift., Evaluation, Forklift to be replaced during 2020, Follow up action raised for June 2020 review.Closed2-Dec-19
32Powerboard Used IncorrectlyAuditPowerboard used incorrectly., Evaluation, Powerboard removed.Closed26-Jun-19
31SDS Expiry TrefolexSDS - TrefolexEvaluation, SDS Updated 16/01/2020Closed20-Jan-20
30Upol Touch Up PaintSDS - Upol Touch Up Paint , , Actions, , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed13-Aug-22
29Ultimeg 2000/372SDS - Ultimeg 2000/372SDS UpdatedClosed7-Jun-21
28Compliance ReviewLegislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation Reviewed, No Actions Required,  Closed24-Jul-20
27Incorrect Standards ReferenceAuditThe Manual references AS/NZS 4801:2001 rather than AS/NZS ISO 45001:2018, Evaluation, References updated.Closed14-Jun-19
26Methylated SpiritsSDS - Methylated SpiritsSDS UpdatedClosed6-Sep-21
25Mineral TurpentineSDS - Mineral TurpentineSDS UpdatedClosed6-Sep-21
24Megapoxy E155 - Part BSDS - Megapoxy E155 - Part BActions, , Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed10-Aug-22
23Isonel 31HFSDS - Isonel 31HFActions, , , SDS Updated, Access to online SDS Library implemented., Current versions of individual SDS available as needed.Closed10-Aug-22
22Incorrect Ambient TemperatureFault The ambient temperature was marked as 35 Deg instead of 50 Deg., Customer identified error at pickup., Evaluation, A non standard temperature was required by this specification which was not highlighted on the design from Star Delta, Star Delta requested to highlight different than standard parameters.Closed10-Jun-19
21Incorrect VoltageFaultTransformer did not pass inspection., Star Delta identified the number of turns as per their equipment which is different to HGrant transformer's equipment., Evaluation, Both winding patterns included on design.Closed10-Jun-19
20OFI #1 - 2018 Lessons LearnedAuditApproach to recording lessons learned may be formalised to further enhance continual improvement in the organisation., Evaluation, , The section Organisational Knowledge has been added to the Management System Manual to describe the processes used to maintain and develop organisational knowledge. Lessons learned is included in this section., Lessons Learned has been included as a formal agenda item for Management ReviewClosed15-Nov-18
19Payment ProcessingImprovementThe processes used for the financial payments is not adequately documented., Evaluation, The following Work Method Statements have been created to describe various business processes:, , Payroll, BAS Statements, End of Month Payments, Payments from CreditorsClosed13-Nov-18
18Compliance ReviewLegislation SummaryReview of Applicable Legislation, Evaluation, Identified Legislation reviewed., No Actions RequiredClosed18-Jun-19
17Compliance ReviewLegislation SummaryThe following legislation has been reviewed:, , AS/NZS 60076:2014, , No actions required.Closed1-Aug-18
16Document OwnersAuditNot all documents have been assigned an owner, Evaluation, All documents updated to include document owner. Refer Documents RegisterClosed1-Aug-18
15System AwarenessManagement Review August 2018System Awareness training to be conducted at the Operations meeting, Evaluation, With the upgrade of the system to include WHS, the Awareness package has been replaced by a complete Induction package.Closed1-Mar-19
14Quotation ResponseManagement Review August 2018It was noted that a lower expected response for Quotation Response was received from Ekka., Evaluation, Customer contected to determine details of issues and develop a correction strategy., Discussions on ex stock versus bespoke transformers.,  Closed3-Sep-18
13Maintenance ScheduleOperationsIt was noted that the current Maintenance Schedule exipred in June., Evaluation, , Maintenace Schedule updated for 2019/2019, Template created.Closed11-Apr-19
12Purchasing RecordsAuditPurchasing records currently maintained are not referenced in the system., Evaluation, MYOB Records included in the Records RegisterClosed1-Aug-18
11Weekly MeetingsAuditThe procedure references Toolbox Talks rather than the Weekly Operations Meeting., Evaluation, Procedure updated accordligly.Closed1-Aug-18
10OHS ActAuditThe procedure does not reference the correct WHS Legislation, Evaluation, Procedure updated to reference the OHS Act 1984Closed1-Aug-18
9Environmental ReferencesAuditThe manual references Environmental Policies and Objectives however the system is not an Environmental Management System, Evaluation, Manual updated to correct references.Closed30-Jul-18
8Organisational KnowledgeAuditThe manual addresses Organisational Knowledge but does not define the arrangements in place to manage this requirement., Evaluation, Management System Manual updated to include references to current information systems.Closed1-Aug-18
7PlanningAuditIt is not clear how the planning process interfaces with the production process., Evaluation, Production schedules are determined by the Factory Manager based on delivery requirements and stock availability., Jobs are issued accordingly, Upcoming jobs are identified on the Planning Board in the Factory Office., Procedure updated accordingly.Closed1-Aug-18
6Production RecordsAuditIt is not clear what records are maintained from the testing processes., Evaluation, Test results are recorded on the job (BOM) paperwork., Procedure updated accordingly.Closed1-Aug-18
5Staff LimitationsAuditThe small number of staff may limit the Organisation's ability to manage change. , This should be included as a Business Risk, Evaluation, Critical Skills has been included as a Business Risk - Refer Risk #1650, Additionalm Staff to be hired.Closed1-Aug-18
4Machinery Set-upAuditIt is not clear what criteria are used for machinery set-up, Evaluation, Machinery Set-Up is managed as follows:, , Specific product requirements are detailed in the BOM - Procedure Service Delivery updated to better reflect this, Set-up is conducted by a competent operator. Competency is detailed in the Skills Matrix and the People RegisterClosed1-Aug-18
3Requirements - SalesAuditIt is not clear whether there are statutory or regulatory requirements that need to be considered., Evaluation, AS 60076 has been identified as the standard against which transformers are manufactured., The Legislation Register has been updated accordingly.Closed1-Aug-18
2Quality Policy - Interested PartiesAuditIt is not clear how the policy is made available to interested parties., Evaluation, Quality Policy available through the company websiteClosed1-Aug-18
1Communication of Quality PolicyAuditIt is not clear how the policy is communicated to employees., Evaluation, The Qulaity Policy is comumicated through the following:, , The company website;, The Management System;, The Quality Awareness training package;, Notice BoardsClosed1-Aug-18